View Issue Details [ Jump to Notes ] | [ Issue History ] [ Print ] |
ID | Project | Category | View Status | Date Submitted | Last Update |
0000225 | Rosetta | [All Projects] Crash | public | 2013-03-20 21:05 | 2013-03-20 22:09 |
|
Reporter | rpache | |
Assigned To | rmoretti | |
Priority | normal | Severity | crash | Reproducibility | always |
Status | resolved | Resolution | fixed | |
Platform | All platforms | OS | Any | OS Version | Any |
Product Version | All | |
Fixed in Version | | |
|
Summary | 0000225: Segmentation fault when loading a structure with ligand params file that contains a PROTON CHI line |
Description | Rosetta produces a segmentation fault when loading a structure with a small molecule ligand, where the params file contains a PROTON CHI definition line and no other CHI angle definitions. |
Steps To Reproduce | This can easily be reproduced with the score app. |
Additional Information | The crash does not happen, when the ligand params file contains normal CHI angle def lines. |
Tags | No tags attached. |
|
Application(s) Affected | probably all |
Command Line Used | score.macosgccrelease -database rosetta_database -s 1ZHZ_liganded_renumbered.pdb -extra_res_fa 1ZHZ_LG.fa.params |
Developer Options | |
Fixed in SVN Version | 54418 |
|
Attached Files | bug.tar.gz [^] (74,799 bytes) 2013-03-20 21:05 |
|