| Summary | 0000138: InterfaceAnalyzer mishandles cross-interface disulfides |
| Description | InterfaceAnalyzer fails to treat cross-interface disulfides as broken in the separated state, leading to grossly incorrect dg_separated values, poisoned by about 6000 REU worth of disulfide energies. It is unclear how it should treat interfaces linked by a cross-chain disulfide.
A) Refuse to score such poses?
B) Perhaps score as disulfide in the complex case, and score as not-disulfide in the separated case (with repackable cysteines)?
C) Perhaps B but in both cases multiply the disulfide terms by zero post-scoring? (turning them off in the scorefunction may result in incorrect packing?) |
| Tags | No tags attached. |
|
| Application(s) Affected | InterfaceAnaylzerMover and its app |
| Command Line Used | InterfaceAnaylzer -s 1s78.pdb (an antibody FAB with cross-chain disulfides; use the CH1/CL subcomplex) |
| Developer Options | Confirmed As Bug |
| Fixed in SVN Version | |
|
| Attached Files | |
|